Error Code 15C
Ice room thermistor is out of range
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 15C
What This Means
Failed ice room thermistor; Bad connector contact at CN90 pin 2; Wiring short or open
What actually causes this:
Failed thermistor in ice room compartment
First Thing to Check
Measure resistance at CN90 pins 2 to 4 with power off
Parts Involved
How to Fix
- 1
With power off, measure resistance at CN90-2(GRY) to CN90-4(YEL)
- 2
With power on, measure voltage at CN90-2(GRY) vs CN90-13 (GND): should be 0.6V to 4.6V
- 3
Check MICOM IC01 pin #11 input voltage
- 4
Verify R919 resistor on PCB
This Error Applies To
Samsung RF28R7551S Series Refrigerators (2019) (2019–present)
Related Error Codes
Refrigerator temperature is abnormally high
Humidity sensor voltage is outside valid range (0.6V to 4.7V)
Ice maker thermistor is out of range — ice making may be disrupted
Ice maker motor did not complete its initialization cycle
Freezer temperature is abnormally high
Flex zone compartment temperature is abnormally high