Samsung Refrigerators2023–present

Error Code 13C

Humidity sensor reporting abnormal value

Moderate

Address soon - your appliance may not work properly

Also displayed as: 13C

What This Means

Sensor housing separated; Incomplete connector contact; Open-circuited wire; Short-circuit; No DC 5V supply to sensor

What actually causes this:

The humidity sensor in the top table area has lost power or the sensor itself has failed — common after moisture exposure.

First Thing to Check

Open the top table cover and confirm the sensor connector is fully seated.

Parts Involved

Humidity sensorMain PCB CN90

How to Fix

  1. 1

    Verify Main PBA connector CN90 is inserted properly

  2. 2

    Check if DC 5V is supplied to the humidity sensor (pins #1-#2 of sensor connector)

  3. 3

    Check output voltage at humidity sensor connectors #4-#2; normal range is 1V–4V

  4. 4

    Check voltage between Main PCB CN90 pins 4 and 2; should be 3.68V–0.98V

  5. 5

    Replace humidity sensor if output is abnormal with correct supply voltage

This Error Applies To

Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)

Service manual exact match: RF29C*Service manual exact match: RF23C*Service manual exact match: RF29CB9900QKAAService manual exact match: RF23CB9900QKAAService manual exact match: RF23CB99008MACService manual exact match: RF**CB9900*