Error Code 6C
Ambient air temperature sensor reading invalid
Moderate
Address soon - your appliance may not work properly
Also displayed as: 6C
What This Means
Sensor housing separated; Incomplete connector contact; Open-circuited wire; Short-circuit
What actually causes this:
The external sensor in the top table assembly has lost its connector or the thermistor has failed.
First Thing to Check
Open the top table cover (3 screws) and check that the sensor connector is seated.
Parts Involved
How to Fix
- 1
Check voltage between Main PCB CN90 pins 3 and 2; should be within 4.1V–0.6V range
- 2
Verify Main PBA connector CN90 is inserted properly
- 3
Check resistance between CN90 #12 to #2 and compare to temperature table
- 4
Replace sensor if out of range
This Error Applies To
Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)
Related Error Codes
Ice Bites ice maker temperature sensor reading invalid
Internal I/O expander chip on Main PCB has lost communication
Freezer defrost sensor reading out of valid range
Freezer evaporator fan not running or not sending feedback signal
Flex Crisper compartment sensor out of valid range
Fridge compartment defrost sensor reading out of valid range
Fridge evaporator fan not running or not sending feedback
FlexZone fan not running or not sending feedback signal