Error Code 7C
Flex Crisper compartment sensor out of valid range
Moderate
Address soon - your appliance may not work properly
Also displayed as: 7C
What This Means
Sensor housing separated; Incomplete connector contact; Open-circuited wire; Short-circuit
What actually causes this:
Sensor connector dislodged inside the Flex Crisper compartment.
First Thing to Check
Inspect the sensor connector at the Flex Crisper compartment walls.
Parts Involved
How to Fix
- 1
Check voltage between Main PCB CN60 pins 5 and 3; should be within 4.5V–1.0V range
- 2
Inspect sensor connector and housing
- 3
Replace sensor if voltage out of range
This Error Applies To
Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)
Related Error Codes
Ice Bites ice maker temperature sensor reading invalid
Internal I/O expander chip on Main PCB has lost communication
Ambient air temperature sensor reading invalid
Freezer defrost sensor reading out of valid range
Freezer evaporator fan not running or not sending feedback signal
Fridge compartment defrost sensor reading out of valid range
Fridge evaporator fan not running or not sending feedback