Error Code 31
Ice supply pipe heater circuit has an open or short fault
Moderate
Address soon - your appliance may not work properly
Also displayed as: 31
What This Means
Ice Pipe Heater housing connector separated; Wire disconnection; Short circuit in heater; Open circuit in heater element
What actually causes this:
The small DC heater on the ice water pipe has failed open, which can cause ice blockages in the water line.
First Thing to Check
Disconnect the heater connector and measure resistance with a multimeter — it should read approximately 62 ohms.
Parts Involved
How to Fix
- 1
Check resistance between Main PCB CN20 pins 19 and 23; expected value approximately 62Ω
- 2
If open circuit (infinity): heater wire or element failed
- 3
If short circuit (0Ω): heater element shorted
This Error Applies To
Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)