Error Code 9C
FlexZone compartment sensor out of valid range
Moderate
Address soon - your appliance may not work properly
Also displayed as: 9C
What This Means
Sensor housing separated; Incomplete connector contact; Open-circuited wire; Short-circuit
What actually causes this:
Sensor connector loose or thermistor failed inside the FlexZone evaporator area.
First Thing to Check
Inspect the FlexZone evaporator cover area for a loose sensor connector.
Parts Involved
How to Fix
- 1
Check voltage between Main PCB CN40 pins 14 and 16; should be within 4.5V–1.0V range
- 2
Inspect sensor connector in the Flex Room compartment
- 3
Replace sensor if out of range
This Error Applies To
Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)