Error Code CE3
Compressor rotor position could not be detected during startup
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: CE3
What This Means
Compressor wire connections loose or open; Solder joint fault on inverter PCB; Short circuit on inverter PCB; Compressor motor fault
What actually causes this:
Compressor wiring connector loose or inverter board component failure.
First Thing to Check
Inspect the compressor wire connector CN04 on the inverter board for proper seating.
Parts Involved
How to Fix
- 1
Check compressor wire connections at CN04
- 2
Check soldering status of inverter PCB
- 3
Verify no parts have short-circuited on inverter PCB
- 4
Check compressor winding resistance
This Error Applies To
Samsung RF29CB9900 Series Refrigerators (2023) (2023–present)
Related Error Codes
Door showcase heater has an open or short circuit fault
Ice Bites ice maker temperature sensor reading invalid
Internal I/O expander chip on Main PCB has lost communication
Ambient air temperature sensor reading invalid
Freezer defrost sensor reading out of valid range
Freezer evaporator fan not running or not sending feedback signal
Flex Crisper compartment sensor out of valid range
Fridge compartment defrost sensor reading out of valid range