Error Code 82E

Compressor power module detected internal fault

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 82 E

What This Means

IPM internal fault detection; Overvoltage at IPM; Overcurrent condition; Temperature fault in IPM

What actually causes this:

The power inverter module controlling the compressor failed or overheated.

First Thing to Check

Check if the inverter PCB is hot or shows any burn marks or discoloration.

Parts Involved

IPM (FNE41060)Inverter PCBCompressor U,V,W leads

How to Fix

  1. 1

    Check COMP wire connections U, V, W at IPM

  2. 2

    Check PCB bottom side solder joints around R1

  3. 3

    Check compressor cycle operation

  4. 4

    Verify input voltage stability

This Error Applies To

Samsung RS25H51 Series Refrigerators (2014) (2014–present)

Service manual exact match: RS25H5121BC/AAService manual exact match: RS25H5111WW/AAService manual exact match: RS25H5111SR/AAService manual exact match: RS25H5121SRService manual exact match: RS25H5111BCService manual exact match: RS25H5121WWService manual exact match: RS25H5113SLService manual exact match: RS25H5111SR+2 more