Error Code 07
Ambient temperature sensor open or shorted — affects defrost timing and efficiency
Moderate
Address soon - your appliance may not work properly
Also displayed as: Left - ① LED ON
What This Means
Connector slipped out or missing; Contact failure on connector; Electric wire cut or damaged; Short circuit condition; Ambient temperature sensor failure; Sensor exposed to direct airflow interference
What actually causes this:
Broken wire at upper hinge or failed thermistor in hinge cover
First Thing to Check
Check CN30 #1 to #2 voltage (1.0V~4.5V expected)
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN30 #1 and #2
- 2
Voltage should be within range of 4.5V to 1.0V
- 3
Verify connector is fully seated
- 4
Inspect sensor location for airflow bypass
This Error Applies To
Samsung RS25J5008S Series Refrigerators (2014) (2014–present)
Related Error Codes
Ice maker has failed its automatic cycle three times in a row
Freezer compartment thermistor is open or shorted
The damper air-door heater circuit is open — refrigerator temperature control may be affected
Inverter-driven compressor cannot start or is being protected from abnormal electrical condition
Ice maker temperature sensor open/short or disconnected
Freezer evaporator fan not spinning — freezer will warm up
Refrigerator compartment thermistor open or shorted
Condenser fan not running — compressor will overheat and refrigerator will not cool