Error Code 10
Freezer evaporator fan not spinning — freezer will warm up
Moderate
Address soon - your appliance may not work properly
Also displayed as: Left - ④ LED ON
What This Means
Freezer fan motor mechanical failure or jam; Motor speed feedback signal loss; Motor wire disconnected or cut; Blower fan impeller damage or obstruction; Fan connector loose or corroded; Motor capacitor failure
What actually causes this:
Ice locked fan blade, failed BLDC motor, or broken FG feedback wire
First Thing to Check
Check CN75 #1 to #4 for 7V~12V; listen for motor running
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN75 #1(GRAY) and #4(YELLOW)
- 2
Voltage should be 7V~12V
- 3
Verify motor connector is fully seated
- 4
Spin fan blades by hand to check for jamming
- 5
Listen for motor operation sound
This Error Applies To
Samsung RS25J5008S Series Refrigerators (2014) (2014–present)
Related Error Codes
Ice maker has failed its automatic cycle three times in a row
Freezer compartment thermistor is open or shorted
The damper air-door heater circuit is open — refrigerator temperature control may be affected
Inverter-driven compressor cannot start or is being protected from abnormal electrical condition
Ambient temperature sensor open or shorted — affects defrost timing and efficiency
Ice maker temperature sensor open/short or disconnected
Refrigerator compartment thermistor open or shorted
Condenser fan not running — compressor will overheat and refrigerator will not cool