Error Code E CF
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CF
How to Fix
- 1
Step 1: Reset unit and enter Test Mode 1 (push test button 1 time). Measure condenser fan motor supply voltage at CON4 24th Pin ~ 23rd Pin. If NOT 11.4~12.6V, replace Main PCB.
- 2
Step 2: Check fan rotation visually. If fan is not rotating, proceed to step 3.
- 3
Step 3: Manually rotate condenser fan blade by hand. If fan feels sticky/binding, replace fan motor.
- 4
Step 4: Go to step 5.
- 5
Step 5: Measure fan motor feedback voltage at CON4 22nd Pin ~ 23rd Pin. If reads 0V or 5V (not fluctuating), replace fan motor.
- 6
Step 6: Measure PWM signal voltage at CON4 21st Pin ~ 23rd Pin. If reads 0V or 5V (not fluctuating), replace Main PCB.
- 7
Step 7: If all voltages are correct, explain to customer — condenser fan is operating normally.
Other Error Codes for LRYXC2606D
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection
Defect of freezer defrost sensor — short-circuit or disconnection of defrost sensor
Defect of UVC LED — UVC LED disconnected or UVC LED failure. Check UVC LED connection.
Defect of room temperature sensor (RT sensor) — short-circuit or disconnection
Defect of humidity sensor — short-circuit or disconnection of humidity sensor
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor