Error Code E IF
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E IF
How to Fix
- 1
Step 1: Reset unit and enter Test Mode 1 (push test button 1 time). Measure fan motor supply voltage at CON4 12th Pin ~ 11th Pin. If NOT 11.4~12.6V, replace Main PCB.
- 2
Step 2: Open freezer door and check for airflow in ice compartment. If windy, proceed to step 5.
- 3
Step 3: If no airflow, manually rotate fan blade by hand. If fan feels sticky/binding, replace fan motor.
- 4
Step 4: Go to step 5.
- 5
Step 5: Measure feedback voltage at CON4 10th Pin ~ 11th Pin. If reads 0V or 5V (not fluctuating), replace fan motor.
- 6
Step 6: Measure PWM voltage at CON4 9th Pin ~ 11th Pin. If reads 0V or 5V (not fluctuating), replace Main PCB.
- 7
Step 7: If all voltages are correct, explain to customer — icing fan is operating normally.
Other Error Codes for LRYXC2606D
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection
Defect of freezer defrost sensor — short-circuit or disconnection of defrost sensor
Defect of UVC LED — UVC LED disconnected or UVC LED failure. Check UVC LED connection.
Defect of room temperature sensor (RT sensor) — short-circuit or disconnection
Defect of humidity sensor — short-circuit or disconnection of humidity sensor
Defect of flow meter or lack of water supply — malfunction of flow meter. Check connection of flow meter and water supply.
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor