Error Code 76

AutoFill pitcher overflow sensor has detected water overflow

Moderate

Address soon - your appliance may not work properly

Also displayed as: 76

What This Means

Overflow sensor detects actual water overflow; Overflow sensor housing separated; Contact error or disconnection in sensor circuit; AutoFill valve stuck open

What actually causes this:

Pitcher overfilled or overflow sensor circuit has a fault.

First Thing to Check

Remove the AutoFill pitcher and check for standing water in the pitcher bay.

Parts Involved

AutoFill overflow sensorMain PCB CN60AutoFill water valve

How to Fix

  1. 1

    Check voltage between Main PCB CN60 pins 7 and 3

  2. 2

    0V–4.5V: water overflow detected (actual overflow or sensor fault)

  3. 3

    4.5V–5V: no overflow (sensor is normal)

  4. 4

    Inspect AutoFill pitcher area for standing water

  5. 5

    Check sensor connector and wiring at CN60

Need more help with your Samsung RF23CB9900QKAA?