Error Code ㉝
The freezer ice pipe heater isn't warming up
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks in self-diagnostic checklist position 28
What This Means
Ice pipe heater shorted (0Ω reading); Ice pipe heater wire open circuit (∞Ω reading); Bimetal protector defective; Harness damaged or disconnected
What actually causes this:
The heater element failed or its wire came loose
First Thing to Check
Check if ice clogs the dispenser pipe or if ice doesn't flow properly
Parts Involved
How to Fix
- 1
1. Unplug refrigerator and wait 5 minutes
- 2
2. Disconnect MAIN PCB CN90 wire from PCB
- 3
3. Measure resistance between CN90 pins 1 and 5 (power OFF)
- 4
4. Should read 63Ω ± 7% (115V) or 230Ω ± 7% (230V)
- 5
5. If 0Ω: short circuit; if ∞Ω: open circuit