Error Code ⑦
The Cool Select Pantry temperature sensor isn't working
Moderate
Address soon - your appliance may not work properly
Also displayed as: LED blinks in self-diagnostic checklist position 7
What This Means
Pantry thermistor (502AT) disconnected; Wire harness damaged between Pantry compartment and Main PBA; Thermistor defective (open circuit or short); Main PBA defect
What actually causes this:
The Pantry sensor wire came loose or the sensor failed
First Thing to Check
Check that the Cool Select Pantry maintains appropriate temperature despite the error
Parts Involved
How to Fix
- 1
1. Measure voltage at MAIN PCB CN40 between pins 18 and 20 — must be 4.5V to 1.0V
- 2
2. Check connector at Cool Select Pantry temperature sensor
- 3
3. Disconnect CN40 and measure thermistor resistance directly (power off)
- 4
4. At 77°F (25°C), should read 5.0 kΩ
- 5
5. If resistance is normal, replace Main PBA
Other Error Codes for RF23R6201ED
The main board's input/output controller isn't responding
The freezer temperature sensor isn't reading correctly
The outside temperature sensor isn't reading correctly
The refrigerator temperature sensor isn't reading correctly
The refrigerator ice room heater isn't warming up
The ice room temperature sensor isn't reading correctly
The ice room cooling fan isn't running
The freezer defrost sensor isn't reading temperature correctly