Error Code COMP-IPM-SHUTDOWN
Compressor inverter power module has forcibly shut down
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks per inverter protection table
What This Means
PCB solder short on inverter circuit; DC 15V output below 13.5V; Compressor or cycle fault
What actually causes this:
The intelligent power electronics protecting the compressor detected a dangerous condition and shut everything down.
First Thing to Check
Unplug the fridge for 10 minutes and try restarting — if it happens again immediately, professional service is required.
Parts Involved
How to Fix
- 1
Check inverter PCB soldering for short circuits
- 2
Verify DC 15V output is above 13.5V
- 3
Check compressor and refrigeration cycle
Other Error Codes for RF25C5551SR
Refrigerator compartment temperature is abnormally high
Freezer defrost sensor is faulty and cannot detect when defrost is complete
Refrigerator humidity sensor is faulty
External ambient temperature sensor is faulty
Freezer evaporator fan motor is not running
Refrigerator compartment temperature sensor is faulty or disconnected
Ice Bites maker temperature sensor is faulty
Refrigerator compartment fan is not running