Error Code COMP-MOTOR-CONSTRAINT

Compressor motor is jammed or running at dangerously low speed

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: LED blinks per inverter protection table

What This Means

Locked rotor operating within 5 seconds; Compressor operating below 1000 RPM for more than 5 seconds; Large sudden input voltage change; Failed compressor or refrigeration cycle blockage

What actually causes this:

The compressor is unable to spin at the correct speed, usually because it is mechanically seized or there is a fault in the position sensing circuit.

First Thing to Check

Listen for the compressor humming loudly without running — that sound indicates a seized motor.

Parts Involved

Inverter compressor NF54M5151ARTT3MAIN PCB resistor R2 (0.09Ω)CN102

How to Fix

  1. 1

    Check compressor wire connections at CN102

  2. 2

    Verify resistance of R2 (0.09Ω) on PCB

  3. 3

    Inspect MAIN PCB soldering

  4. 4

    Check compressor and refrigeration cycle