Error Code 29

FlexZone fan not running or not sending feedback signal

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 29

What This Means

Feedback signal line contact error; Motor wire separation; Defective FlexZone BLDC fan motor

What actually causes this:

Fan motor seized or wiring damaged inside the FlexZone evaporator cover.

First Thing to Check

Enter Forced Run mode and listen at the FlexZone compartment for fan operation.

Parts Involved

FlexZone BLDC fan motor (12035GE-12M-YT-F1)Main PCB CN20Main PCB CN40

How to Fix

  1. 1

    Check feedback signal between Main PCB CN20 pins 20 and 24

  2. 2

    Fan running correctly produces a specific frequency pulse

  3. 3

    Check drive voltage between CN40 #13 and #15 (DC 7–12V)

  4. 4

    Verify FlexZone door switch is closed