Error Code 2E
Refrigerator temperature sensor fault or disconnect
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 2 E
What This Means
Connector slipped out or open contact; Wire cut or short circuited; Abnormal sensing temperature
What actually causes this:
Temperature sensor connector becomes loose or thermistor fails
First Thing to Check
Push connector CN30 #5 firmly to ensure good connection
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN30 #5 and #7
- 2
Voltage should be within 4.5V to 1.0V range
Other Error Codes for RH25H5611SR
Refrigerator compartment temperature too warm
Compressor power supply internal module failure
Freezer defrost sensor malfunction or open circuit
Humidity sensor failure or circuit open
Ice maker sensor malfunction or open circuit
Condenser cooling fan motor failure or no speed feedback
Main control board cannot communicate with display panel
Ice maker cannot eject ice cubes or crushed ice