Error Code 13E

Humidity level sensor malfunction

Minor

Usually easy to fix - may resolve on its own

Also displayed as: 13 E

What This Means

Separation of sensor housing part; Contact error; Disconnection; Short circuit

What actually causes this:

The humidity sensor connector came loose or the sensor itself failed.

First Thing to Check

Locate the humidity sensor connector and reseat it firmly.

Parts Involved

SENSOR HUMIDITY DA32-00034BMAIN PCB CN30

How to Fix

  1. 1

    Measure voltage between MAIN PCB CN30 #7 and #9

  2. 2

    Voltage should be within range 4.5V to 1.0V

  3. 3

    Check sensor pin #1-#2 voltage approximately 5V

  4. 4

    Check output voltage on pin #3 approximately 1-4V

Need more help with your Samsung RS25H5111BC?