Error Code 4E

Freezer defrost temperature sensor malfunction

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 4 E

What This Means

Connector Slipped-Out or Open-Contact; Wire Cut or Short-Circuited; Abnormal Sensing Temperature (above +50°C or below -50°C)

What actually causes this:

The freezer defrost sensor failed, so the system can't tell when to start or stop the defrost cycle.

First Thing to Check

Locate the defrost sensor near the freezer evaporator and check for loose connections.

Parts Involved

Thermistor (Freezer Evaporator) DA32-00029QMAIN PCB CN30

How to Fix

  1. 1

    Measure voltage between MAIN PCB CN30 #4 and #7

  2. 2

    Voltage should be within range 4.5V to 1.0V

  3. 3

    During defrost, sensor should read lower than -5°C