Error Code AE6
The motor speed controller lost its connection to the main control board
Moderate
Address soon - your appliance may not work properly
Also displayed as: AE6
What This Means
Signals between Inverter PBA and main PBA not sensed due to communication error; Incorrect or loose connector connections between Inverter PBA and main PBA; Faulty soldering on Inverter PBA
What actually causes this:
The connector between the motor controller and the main board came loose
First Thing to Check
Turn off the washer, unplug it for 5 minutes, then plug it back in and try again
Parts Involved
How to Fix
- 1
1. Check connector connections between Inverter PBA and main PBA carefully — look for incorrect or loose connections
- 2
2. Remove the Inverter PBA and check for any faulty soldering
- 3
3. If connections are secure and soldering is intact, replace the Inverter PBA or Main PBA
Other Error Codes for WF42H5200AP
The WiFi module in your washer lost its connection to the main board
The control panels inside your washer aren't communicating with each other
The display panel lost its connection to the main control board
One of the buttons on your washer is stuck
The water heater in your washer isn't working properly
Your washer door isn't closing or locking properly
The washer motor is struggling to spin the drum
The incoming water is too hot for the selected cycle