Error Code d95
FlowSense duct blockage – ductwork is approximately 95% blocked (displayed for 2 hours after cycle ends)
Moderate
Address soon - your appliance may not work properly
Also displayed as: d95
How to Fix
- 1
Follow all steps for d90 error – blockage is more severe.
- 2
Do not operate dryer until exhaust system is fully cleared and repaired.
- 3
Check outside dryer vent while dryer is operating to confirm strong airflow.
- 4
If exhaust system run is extremely long, have it rerouted to meet maximum duct length requirements.
- 5
Opening the door or pressing POWER button will clear the display, but the underlying restriction must be corrected.
Other Error Codes for DLG8401VE
Temperature sensor (thermistor) failure – thermistor shorted
FlowSense duct blockage indicator – four bars shown during drying cycle or 'dso' shown after drying; significant ductwork restriction detected
Temperature sensor (thermistor) failure – thermistor open circuit
Humidity sensor (electrode/moisture sensor) failure
Power supply error – electric dryer power cord not connected correctly or house power supply is incorrect / insufficient voltage (below 240V on L1-L2 leg reaching PCB)
FlowSense duct blockage – ductwork is approximately 90% blocked
No power / power cord not connected correctly (electric dryer only)
Gas supply failure – gas not being supplied to the dryer (gas model only)