Error Code tE2
Outlet thermistor (blower housing) open or shorted — Temperature sensor error 2. Displayed during drying cycle or test mode.
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
What This Means
Outlet thermistor open or shorted (secondary check); Harness wiring fault; Defective main PCB
How to Fix
- 1
Follow the same procedure as tE1
- 2
Turn off power and discharge voltage before measuring
- 3
Remove NA6 connector from controller and short pin 2 (Blue) and pin 3 (Orange)
- 4
If fault clears with pins shorted, check harness connections and reconnect, or replace controller if still faulty
- 5
If fault persists with pins shorted, measure thermistor resistance and compare to Table 1 temperature-resistance chart
- 6
Replace thermistor if out of specification
- 7
If thermistor measures correctly, inspect harness-linking connector for damage or poor contact