Error Code nP
No power / power supply issue - electric dryer power cord not connected or house power supply incorrect
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
How to Fix
- 1
Check outlet voltage — should be 110–125 VAC at L1/L2.
- 2
If outlet voltage is out of range, check house fuse or circuit breaker.
- 3
Measure voltage between connector BK or WH (Black Wire) at controller and BL2 (White Wire) — should be 110–125 VAC.
- 4
If voltage is present at outlet but not at controller, check if power cord is properly connected.
- 5
Verify controller wire is not disconnected and terminal block connection is secure.
- 6
Confirm that power cord neutral (N) line connects to center terminal (N) on terminal block.
- 7
If all connections are correct and power is present, replace the controller.
This Error Applies To
LG DLEX4200B Series Dryers
Related Error Codes
Steam water supply pump failure detected in test mode
Thermistor of blower housing - Outlet thermistor open or shorted
Power supply wire connection wrong or loose (Black-White-Red)
NFC module open or shorted
Exhaust ductwork approximately 80% blocked - FlowSense alert
Power failure - house fuse blown or circuit breaker tripped, or power outage occurred
NFC module type is wrong
Exhaust ductwork approximately 90-95% blocked - FlowSense alert