Error Code d90
FlowSense duct blockage at approximately 90% — ductwork critically restricted. Error displayed for 2 hours.
Moderate
Address soon - your appliance may not work properly
Also displayed as: d90
What This Means
Ductwork approximately 90% blocked; Crushed or damaged exhaust duct; Severely obstructed exterior vent hood
How to Fix
- 1
Stop using dryer immediately — operating with d90 presents a fire risk
- 2
Inspect and clean the entire exhaust duct system before further use
- 3
Check outside vent hood for lint clogging or damage
- 4
Check that area around vent hood exterior is clear
- 5
If exhaust system is extremely long, have it repaired or rerouted by a qualified installer
- 6
Keep area around dryer clear of clutter
- 7
After remediation, confirm exhaust system is fully clear before resuming operation
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
Humidity sensor failure.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.