Error Code dE
Door switch abnormal. Displayed in test mode only.
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
What This Means
Door switch open or shorted; Door frame knob not actuating switch; Harness connector loose
How to Fix
- 1
Enter diagnostic test mode to confirm dE code
- 2
Turn off power before measuring resistance
- 3
With door closed: measure resistance between BL2 white wire and BK2 black wire connector (after removing BL2 and WH4 from controller); expect below 2500 Ω
- 4
If above 2500 Ω with door closed: check door switch per component testing procedure — door closed should read COM-NO resistance below 1 Ω
- 5
With door open: measure resistance between BL2 white wire and BK2 black wire; expect 300–600 Ω (lamp resistance in circuit)
- 6
If lamp resistance is not in range, check interior lamp and replace if necessary, then re-measure
- 7
Measure resistance between WH4 yellow wire and BL2 white wire with door open; expect below 1 Ω (door switch COM-NC path)
- 8
With door closed, same yellow-to-white measurement should read below 1 Ω via COM-NO path
- 9
If switch readings fail, replace door switch
- 10
If all switch readings pass, check controller and harness-linking connector
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
Humidity sensor failure.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.