Error Code nP
No power detected — power cord not connected correctly or incorrect house power supply
Moderate
Address soon - your appliance may not work properly
Also displayed as: nP
How to Fix
- 1
Check that power cord is fully inserted and terminal block connections are tight
- 2
Confirm neutral (N) line of power cord matches center (N) terminal on block
- 3
Verify voltage at outlet is 110–125 VAC
- 4
Reset circuit breaker or replace blown fuse
- 5
If nP remains, inspect connector BK2/WH2 (black wire) and BL2 (white wire) to controller for 110–125 VAC
- 6
If voltage is present at BK2/BL2 but controller still shows fault, check controller wire connection and replace controller if necessary
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Humidity sensor failure.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.