Error Code nP

No power detected — power cord not connected correctly or incorrect house power supply

Moderate

Address soon - your appliance may not work properly

Also displayed as: nP

How to Fix

  1. 1

    Check that power cord is fully inserted and terminal block connections are tight

  2. 2

    Confirm neutral (N) line of power cord matches center (N) terminal on block

  3. 3

    Verify voltage at outlet is 110–125 VAC

  4. 4

    Reset circuit breaker or replace blown fuse

  5. 5

    If nP remains, inspect connector BK2/WH2 (black wire) and BL2 (white wire) to controller for 110–125 VAC

  6. 6

    If voltage is present at BK2/BL2 but controller still shows fault, check controller wire connection and replace controller if necessary