Error Code PF
Power failure — house power supply issue
Moderate
Address soon - your appliance may not work properly
Also displayed as: PF
How to Fix
- 1
Check that house circuit breaker for the dryer has not tripped; reset if necessary
- 2
Check house fuse; replace if blown — do not increase fuse capacity
- 3
If problem is circuit overload, have it corrected by a qualified electrician
- 4
Verify outlet voltage is 110–125 VAC between L1/N terminals
- 5
Check power cord connection at terminal block
- 6
If PF persists after restoring power, check controller
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Humidity sensor failure.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.