Error Code PS
Power supply wiring error — wire connection wrong or loose (Electric dryer only). Also labeled 'PF' or 'nP' in some displays.
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
What This Means
Power cord wires (Black-White-Red) connected incorrectly to terminal block; Wire connection to terminal block is loose; House fuse blown or circuit breaker tripped
How to Fix
- 1
Verify power cord is correctly connected to terminal block
- 2
Confirm black wire (L1) connects to left terminal, red wire (L2) to right terminal, white wire (neutral) to center terminal
- 3
For 4-wire connection: confirm green ground wire connects to external ground screw and neutral ground wire connects to center screw
- 4
Check that all terminal block nuts are fully tightened
- 5
Verify strain relief is secure
- 6
Restore power and re-test; if PS persists, check house circuit breaker and fuse