LG Dryers2017–present

Error Code PS

Power supply wiring error — wire connection wrong or loose (Electric dryer only). Also labeled 'PF' or 'nP' in some displays.

Moderate

Address soon - your appliance may not work properly

Also displayed as: PS

What This Means

Power cord wires (Black-White-Red) connected incorrectly to terminal block; Wire connection to terminal block is loose; House fuse blown or circuit breaker tripped

How to Fix

  1. 1

    Verify power cord is correctly connected to terminal block

  2. 2

    Confirm black wire (L1) connects to left terminal, red wire (L2) to right terminal, white wire (neutral) to center terminal

  3. 3

    For 4-wire connection: confirm green ground wire connects to external ground screw and neutral ground wire connects to center screw

  4. 4

    Check that all terminal block nuts are fully tightened

  5. 5

    Verify strain relief is secure

  6. 6

    Restore power and re-test; if PS persists, check house circuit breaker and fuse