Error Code tE1
Outlet thermistor (blower housing) open or shorted — Temperature sensor error 1. Displayed during drying cycle or test mode.
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
What This Means
Outlet thermistor open or shorted; Harness connector at NA6 pin loose or disconnected; Defective main PCB
How to Fix
- 1
Enter diagnostic test mode: unit in standby, press Power, then press More Time and Less Time simultaneously for 0.5 seconds
- 2
Press START/PAUSE once to advance to thermistor check step
- 3
Turn off power and disconnect dryer before measuring resistance
- 4
Remove NA6 connector from the controller
- 5
Short pin 2 (Blue Wire) and pin 3 (Orange Wire) of the NA6 connector together with a metal jumper
- 6
If controller shows no error with pins shorted: check that NA6 connector and 6-pin harness are properly connected to controller; if OK, replace controller
- 7
If short test does not clear fault: separate harness from thermistor assembly connector and measure resistance between thermistor terminals
- 8
Compare measured resistance to Table 1 values: at 50°F (10°C) expect 18.0 kΩ, at 70°F (21°C) expect 11.7 kΩ, at 90°F (32°C) expect 7.7 kΩ, at 104°F (40°C) expect 6.2 kΩ
- 9
If resistance is out of range, replace thermistor assembly
- 10
If resistance is in range, check and reseat harness-linking connector between thermistor and controller
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Humidity sensor failure.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.