LG Dryers2017–present

Error Code tE2

Outlet thermistor (blower housing) open or shorted — Temperature sensor error 2. Displayed during drying cycle or test mode.

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE2

What This Means

Outlet thermistor open or shorted (secondary check); Harness wiring fault; Defective main PCB

How to Fix

  1. 1

    Follow the same procedure as tE1

  2. 2

    Turn off power and discharge voltage before measuring

  3. 3

    Remove NA6 connector from controller and short pin 2 (Blue) and pin 3 (Orange)

  4. 4

    If fault clears with pins shorted, check harness connections and reconnect, or replace controller if still faulty

  5. 5

    If fault persists with pins shorted, measure thermistor resistance and compare to Table 1 temperature-resistance chart

  6. 6

    Replace thermistor if out of specification

  7. 7

    If thermistor measures correctly, inspect harness-linking connector for damage or poor contact

This Error Applies To

LG DLEX5000V Series Dryers (2017) (2017–present)

Service manual exact match: DLGX5001VService manual exact match: DLEX5000VService manual exact match: DLGX5001WService manual exact match: DLEX5000WService manual exact match: DLGX5001BService manual exact match: DLEX5000B