LG Dryers2017–present

Error Code tE1

Thermistor of blower housing open or shorted

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE1

How to Fix

  1. 1

    Enter diagnostic test mode: unit in standby, press Power then simultaneously press More Time and Less Time for 0.5 seconds.

  2. 2

    If tE1 displays during diagnostics, disconnect power immediately.

  3. 3

    Remove the NA6 connector from the controller.

  4. 4

    Short the 6-pin NA6 connector Pin 4 (Blue Wire) and Pin 3 (Orange Wire) together with a metal jumper.

  5. 5

    If the tE1/tE2 error clears after shorting, the wiring to the controller is intact — check that NA6 connector and the 6-pin connector are properly connected to the controller.

  6. 6

    If error persists after shorting, reconnect connector and measure resistance between the thermistor terminals after disconnecting the thermistor harness.

  7. 7

    Compare resistance to Table 1: at 50°F (10°C) expect 18.0 kΩ; at 70°F (21°C) expect 11.7 kΩ; at 80°F (27°C) expect 9.3 kΩ; at 90°F (32°C) expect 7.7 kΩ; at 100°F (38°C) expect 6.2 kΩ; at 110°F (43°C) expect 5.2 kΩ; at 120°F (49°C) expect 4.3 kΩ; at 130°F (54°C) expect 2.9 kΩ; at 140°F (60°C) expect 3.0 kΩ; at 150°F (66°C) expect 2.5 kΩ; at 160°F (71°C) expect 2.2 kΩ.

  8. 8

    If resistance is outside range, replace the thermistor assembly.

  9. 9

    If resistance is within range, check and re-seat the harness linking connector between thermistor and controller.

  10. 10

    If all wiring checks pass and error persists, replace the main controller board.

This Error Applies To

LG DLEX7600BE Series Dryers (2017) (2017–present)

Service manual exact match: DLEX7600WEService manual exact match: DLGX7601BEService manual exact match: DLEX7600BEService manual exact match: DLGX7601VEService manual exact match: DLEX7600VEService manual exact match: DLGX7601WE

Need more help with your LG dryers?