Error Code PF
Power failure — same causes as PS code
Moderate
Address soon - your appliance may not work properly
Also displayed as: PF
How to Fix
- 1
Check wall outlet for correct voltage: 110-125V AC.
- 2
Reset circuit breaker or replace blown fuse. Do not increase fuse capacity.
- 3
If problem is circuit overload, have a qualified electrician correct it.
- 4
Verify power cord connection to terminal block.
- 5
Check that neutral wire connects to center terminal block screw.
This Error Applies To
LG DLEY1701VE Series Dryers
Related Error Codes
Humidity/moisture sensor failure
Ductwork approximately 95% blocked — Flow Sense detection — severe restriction
Flow Sense shows 80% duct restriction after a drying cycle — ductwork needs attention
No power detected — power supply issue
Steam pump error — pump AD value below threshold during diagnostic test mode
Installation test mode successfully activated — Flow Sense installation test
Temperature sensor (thermistor) failure — short circuit or secondary thermistor fault
Power supply error — electric dryer power cord not connected correctly, or house power supply is incorrect