Error Code tE2
Temperature sensor (thermistor) failure — short circuit or secondary thermistor fault
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Turn off dryer and unplug from power.
- 2
Discharge capacitors: touch metal plug of power cord to ground.
- 3
Disconnect connector NA6 from the controller.
- 4
Short Pin 5 (Yellow Wire) and Pin 6 (Blue Wire) on the NA6 connector together.
- 5
If controller does not detect short, check NA6 connector seating; if seated properly, replace the controller.
- 6
Remove harness from thermistor assembly connector and measure resistance between thermistor terminals.
- 7
Compare against Table 1 temperature-resistance chart (see tE1 steps).
- 8
If resistance reads near 0 Ω (shorted), replace the thermistor assembly.
- 9
If resistance is in range, check and reseat the harness-linking connector.