Error Code tE1
Temperature sensor (thermistor) failure — open circuit
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
How to Fix
- 1
Turn off dryer and unplug from power.
- 2
Discharge capacitors: touch metal plug of power cord to ground.
- 3
Disconnect connector NA6 from the controller.
- 4
Short Pin 5 (Yellow Wire) and Pin 6 (Blue Wire) on the NA6 connector together using a metal wire.
- 5
If the controller shows connectivity to the shorted pins, check that the NA6 6-pin connector is properly connected to the controller — if connection is good, replace the controller.
- 6
If the short test passes, remove the harness from the thermistor assembly connector and measure resistance between thermistor terminals.
- 7
Compare measured resistance against Table 1: at 50°F (10°C) expect 18.0 kΩ; at 70°F (21°C) expect 9.3 kΩ; at 90°F (32°C) expect 7.7 kΩ; at 100°F (38°C) expect 6.2 kΩ; at 110°F (43°C) expect 5.2 kΩ; at 120°F (49°C) expect 4.3 kΩ; at 130°F (54°C) expect 2.9 kΩ; at 140°F (60°C) expect 3.0 kΩ; at 150°F (66°C) expect 2.5 kΩ; at 160°F (71°C) expect 2.2 kΩ.
- 8
If resistance is out of range, replace the thermistor assembly.
- 9
If resistance is in range, check and reseat the harness-linking connector between the thermistor and controller.
This Error Applies To
LG DLEY1701VE Series Dryers
Related Error Codes
Humidity/moisture sensor failure
Ductwork approximately 95% blocked — Flow Sense detection — severe restriction
Power failure — same causes as PS code
Flow Sense shows 80% duct restriction after a drying cycle — ductwork needs attention
No power detected — power supply issue
Steam pump error — pump AD value below threshold during diagnostic test mode
Installation test mode successfully activated — Flow Sense installation test
Temperature sensor (thermistor) failure — short circuit or secondary thermistor fault