LG Refrigerators

Error Code E CL

Low side cycle leakage

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Use LG SVC App Step 1 to measure evaporator temperature and determine if this is a sealed system problem or customer misuse.

  2. 2

    If temperature shows normal operation: check PCB voltage — if PCB voltage is abnormal, replace Main PCB.

  3. 3

    Use SVC App Step 2 to measure high/low side pressure and recovery time. If recovery time is more than 15 minutes: system is restricted. Proceed to restriction check.

  4. 4

    Check equilibrium pressure. If equilibrium pressure is more than 20 psi: compressor is defective — replace compressor.

  5. 5

    If equilibrium pressure is 20 psi or less: refrigerant is leaked — locate and repair leak.

  6. 6

    Charge system with nitrogen (N2) for pressure test. Check low-pressure parts (evaporator, suction pipe) using bubble test or refrigerant leak detector first.

  7. 7

    If leak is found on low-pressure side: replace leaking part plus both drier and compressor (low-pressure side is below atmospheric pressure during leak, so moisture has likely entered).

  8. 8

    If no leak found on low-pressure side: check high-pressure parts (condenser, drier).

  9. 9

    If leak is found on high-pressure side: replace leaking part plus drier.

  10. 10

    If leak location cannot be found: install UV drier and recheck at next service visit.

  11. 11

    After sealed system repair: error code will disappear automatically when freezer temperature drops to 14°F or below.

This Error Applies To

LG LRFLC2706S Series Refrigerators

Service manual exact match: LRFLC2706S