LG Washers2016–present

Error Code FE

Overflow Error — water level has exceeded the safe level.

Moderate

Address soon - your appliance may not work properly

What This Means

Input leakage at the valves; Drain hose not positioned at the correct height (must be 0.9-1.2 m above floor); Blockages or leaks in the air hose between the tub and the pressure switch; Air leakage at the air hose connector on the outer tub

How to Fix

  1. 1

    Check all inlet valves for input leakage

  2. 2

    Verify drain hose is positioned 0.9-1.2 m (36-48 inches) above the floor

  3. 3

    Enter service mode — check if water level frequency is over 21.0 kHz; if not, check the air chamber and tube for clogs

  4. 4

    If frequency is over 21.0 kHz, check if inlet valve opens when power is not applied — if yes, replace inlet valve assembly

  5. 5

    If inlet valve works continuously when power is applied, replace main PCB assembly

  6. 6

    Inspect and repair any air leakages at the air hose connector on the outer tub and at any connecting parts

  7. 7

    Remove foreign objects from the pressure sensor switch air hose

  8. 8

    Replace pressure sensor switch if necessary

This Error Applies To

LG WT1901CK Series Washers (2016) (2016–present)

Service manual exact match: WT1901CKTService manual exact match: WT1901CKService manual exact match: WT1901CKWService manual exact match: WT1901CKBService manual exact match: WT1901CKV