The vent blockage test found a problem with your exhaust

Moderate

Address soon - your appliance may not work properly

Also displayed as: C1

What This Means

Items left inside the drum during the test; Moisture sensor (dry sensor) malfunction; Moisture sensor dirty or contaminated

What actually causes this:

During the Smart Install vent test, the dryer found the exhaust vent is too restricted for safe operation.

First Thing to Check

Check the exhaust vent hose behind the dryer — make sure it's not kinked, crushed, or full of lint.

Parts Involved

Moisture Sensor (Dry Sensor)

How to Fix

  1. 1

    1. Remove all items from the drum

  2. 2

    2. Check the moisture sensor (dry sensor) for contamination

  3. 3

    3. Clean moisture sensor bars with soft cloth

  4. 4

    4. Re-run the Smart Install vent blockage test

  5. 5

    5. If error persists, test moisture sensor in Smart Install touch sensor check mode

This Error Applies To

Samsung DV54CG7 Series Dryers (2024) (2024–present)

Service manual exact match: DVE54CG7550*Service manual exact match: DVG54CG7550*Service manual exact match: DVE54CG7155*Service manual exact match: DVE54CG7150*Service manual exact match: DVG54CG7150*Service manual exact match: DVE54CG7550VA3Service manual exact match: DVE54CG7550VACService manual exact match: DVG54CG7550VA3+2 more