Samsung Refrigerators2017–present

Error Code 81c

The compressor will not start

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 81c

What This Means

Short between Comp U/V/W pins (CN04); Short between IPM pins (#1~26); IPM Operation Voltage Dropout below DC13.5V; Compressor mechanical issue; Refrigerant cycle blockage

What actually causes this:

Compressor or inverter control board has failed

First Thing to Check

Check that power is reaching the compressor connector

Parts Involved

CompressorInverter PCB

How to Fix

  1. 1

    1. Check for short circuit between Comp U, V, W wires (CN04)

  2. 2

    2. Check IPM pin integrity (pins #1~26)

  3. 3

    3. Measure IPM operation voltage - should be above DC13.5V

  4. 4

    4. Verify compressor is receiving power signal

  5. 5

    5. Check refrigerant cycle for blockage

This Error Applies To