Samsung Refrigerators2017–present

Error Code 82c

The inverter control module for the compressor has failed

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 82c

What This Means

IPM internal circuit failure; IPM overtemperature condition; IPM overload condition; Defective IPM component

What actually causes this:

Power module inside the inverter has failed

First Thing to Check

Check that the inverter PCB is receiving proper power supply

Parts Involved

Inverter PCB with IPM

How to Fix

  1. 1

    1. Check IPM temperature - should not exceed rated limits

  2. 2

    2. Verify IPM operation voltage is within spec

  3. 3

    3. Check for short circuits on IPM output pins

  4. 4

    4. Inspect IPM for physical damage or thermal damage

This Error Applies To

Samsung DRF367500A Series Refrigerators (2017) (2017–present)

Service manual exact match: DRF367500AP/DAService manual exact match: BRF365200AP/AA