Samsung Refrigerators2017–present

Error Code 84c

The compressor is running too slowly or cannot turn

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 84c

What This Means

Compressor restricted for more than 5 seconds; Compressor running at lower than 1000RPM for over 5 seconds; R1 short circuit; Severe fluctuation of input voltage; Mechanical compressor blockage

What actually causes this:

Compressor is stuck or there is a blockage in the refrigerant line

First Thing to Check

Check that the compressor is free to turn by hand (power off)

Parts Involved

CompressorRefrigerant Cycle Components

How to Fix

  1. 1

    1. Check if compressor is mechanically restricted

  2. 2

    2. Verify input AC voltage stability

  3. 3

    3. Check R1 resistor for short circuit

  4. 4

    4. Measure compressor RPM

  5. 5

    5. Check refrigerant lines for blockage

This Error Applies To

Samsung DRF367500A Series Refrigerators (2017) (2017–present)

Service manual exact match: DRF367500AP/DAService manual exact match: BRF365200AP/AA

Need more help with your Samsung refrigerators?