Error Code 29
Convertible zone defrost heater not working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 29C
What This Means
Heater wire harness disconnected at Main PCB CN70_1 pins 7 and 1; Heater element open circuit or burned out; Heater shorted to ground; Bimetal overheating protector tripped; Main PCB defective
What actually causes this:
Defrost heater element failed or thermal protection activated
First Thing to Check
Check if the convertible zone has frost accumulation — indicates heater failure
Parts Involved
How to Fix
- 1
1. Unplug refrigerator
- 2
2. Disconnect Main PCB CN70_1 wire from PCB
- 3
3. Measure resistance between CN70_1-7 and CN70_1-1 — normal 63 ohm ± 7%
- 4
4. If 0 ohm: heater is shorted, replace heater
- 5
5. If infinite: wire or bimetal is open, replace heater
- 6
6. If normal: check thermal protector and fuse operation
This Error Applies To
Samsung RF22N9781 Series Refrigerators (2018) (2018–present)
Related Error Codes
Freezer temperature sensor malfunction
Room temperature sensor not working
Ice maker temperature sensor failure
Fridge temperature sensor is not responding
Convertible zone temperature sensor failure
Ice storage area temperature sensor malfunction
Freezer defrost sensor is faulty
Convertible zone defrost sensor malfunction