Error Code 81
Compressor won't start or keep running
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 81C
What This Means
Inverter PCB soldering defect or short circuit; DC 15V supply below 13.5V from SMPS; Compressor mechanical failure or stuck piston; Compressor thermal protection activated; Inverter gate drive circuit failure
What actually causes this:
Inverter board malfunction or compressor mechanical failure
First Thing to Check
Check if you hear the compressor click when it tries to start
Parts Involved
How to Fix
- 1
1. Check SMPS DC 15V output — must be at least 13.5V
- 2
2. Inspect Inverter PCB for visible solder bridges or short circuits
- 3
3. Check all Inverter PCB components for overheating or damage
- 4
4. Attempt force run in diagnostic mode to test compressor
- 5
5. Listen and feel for compressor mechanical operation
- 6
6. If compressor still doesn't run, check compressor power connections
- 7
7. If power and inverter are normal, compressor may be mechanically stuck
Parts Commonly Needed for This Error
OEM part numbers confirmed by retailers
This Error Applies To
Samsung RF22N9781 Series Refrigerators (2018) (2018–present)
Related Error Codes
Freezer temperature sensor malfunction
Room temperature sensor not working
Ice maker temperature sensor failure
Fridge temperature sensor is not responding
Convertible zone temperature sensor failure
Ice storage area temperature sensor malfunction
Freezer defrost sensor is faulty
Convertible zone defrost sensor malfunction