Error Code COMP_START_FAILURE

Compressor failed to start up properly

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Inverter LED blinks 1 time

What This Means

Short circuit between compressor U, V, or W phase terminals (CN102); Short among IPM pins 1~26 on inverter board; IPM operating voltage dropped below DC 13.5V; Compressor motor winding failure; Refrigerant cycle problem

What actually causes this:

The compressor motor could not get running, possibly because its windings are shorted or the inverter board has failed.

First Thing to Check

Wait 5 minutes for the inverter to reset, then cycle power and listen for the compressor to attempt starting.

Parts Involved

Compressor (NF54K9151AM)Inverter PCB (IPM FNB40560)CN102 connector

How to Fix

  1. 1

    Check for shorts between compressor terminals U, V, W at CN102

  2. 2

    Check IPM voltage — must be above DC 13.5V

  3. 3

    Inspect IPM pins 1~26 for shorts

  4. 4

    If no electrical fault found, check compressor and refrigerant cycle

  5. 5

    Verify 5-minute standby before restart attempt

This Error Applies To

Samsung RF23M80 Series Refrigerators (2017) (2017–present)

Service manual exact match: RF23M80*0**Service manual exact match: RF23M8090SR/AAService manual exact match: RF23M8070SR/AAService manual exact match: RF23M8070SG/AAService manual exact match: RF23M8090SG/SAService manual exact match: RF23M8080SR/EE