Error Code COMP-IPM-SHUTDOWN
Compressor driver power module shut itself down due to a fault
Moderate
Address soon - your appliance may not work properly
Also displayed as: F and R blink — IPM Shut Down pattern
What This Means
DC 15V supply to IPM has dropped below 13.5V; Shorted component on inverter PCB; Overheated IPM module; Compressor or refrigerant cycle fault causing IPM overload
What actually causes this:
The electronic module driving the compressor detected an internal fault and shut itself off to prevent damage.
First Thing to Check
Do not open the unit — call a technician.
Parts Involved
How to Fix
- 1
Check DC 15V at ZD501 on inverter PCB — must be above 13.5V
- 2
Inspect inverter PCB for shorted components (visible burn marks, swollen capacitors)
- 3
Check compressor and refrigerant cycle for root cause of IPM overload
- 4
If 15V supply is low, check SMPS 15V output
This Error Applies To
Samsung RF28T5 Series Refrigerators (2020) (2020–present)