Error Code SPM_FAULT
Inverter power module detected critical electrical fault in compressor circuit
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: SPM Fault
What This Means
Short circuit between compressor U, V, W phases at CN04; Short circuit or internal failure in IPM pins (1-26); Drop in IPM operating voltage below DC 13.5V; Compressor mechanical problem detected by inverter
What actually causes this:
The compressor motor has an internal short circuit or the power inverter detected a dangerous electrical condition
First Thing to Check
Check compressor connector CN04 for visible shorts or damage
Parts Involved
How to Fix
- 1
Check CN04 connector for shorts between U, V, W phases
- 2
Verify DC 13.5V+ at inverter supply
- 3
Inspect IPM (Integrated Power Module) for damage
- 4
Check compressor windings for phase-to-phase shorts
- 5
Verify cooling cycle charge and operation
This Error Applies To
Samsung RF28T5 Series Refrigerators (2020) (2020–present)
Related Error Codes
Refrigerator compartment temperature sensor is disconnected or dead
Internal humidity sensor has failed or is disconnected
Defrost sensor on freezer evaporator is failed or disconnected
Freezer fan motor is not running or not sending feedback
Supply voltage to compressor is too high
Freezer temperature sensor is failing or disconnected
Ice maker temperature sensor in freezer is failed or unplugged
External room temperature sensor is failed or disconnected