Error Code 81
The compressor won't start or keeps stopping
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 81
What This Means
Inverter PCB soldering defect or short circuit; Low DC voltage supply (below 13.5V); Compressor or cycle defect; Main PCB communication failure
What actually causes this:
The compressor control board has a bad solder joint or power supply is too low
First Thing to Check
Check if you hear any buzzing or clicking from the back of the fridge — that indicates compressor trying to start
Parts Involved
How to Fix
- 1
1. Check soldering quality on Inverter PCB for cold joints or shorts
- 2
2. Measure DC 15V output on inverter — should not be less than 13.5V
- 3
3. Check compressor power connections
- 4
4. Verify communication between Main and Inverter PCB
- 5
5. Check refrigerant cycle integrity