Error Code AMBIENT_SENSOR

Ambient temperature sensor malfunction affects cooling control

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Ambient Sensor Error

What This Means

Bad connector contact at CN60 pin 5 and CN90 pin 8; Open circuit in ambient sensor wiring; Short circuit in sensor; Water infiltration or corrosion; Sensor mechanical damage

What actually causes this:

Room temperature sensor lost connection or failed, preventing the refrigerator from adjusting cooling based on room temperature

First Thing to Check

Check that CN60 connector is fully inserted and look for any water damage

Parts Involved

Ambient SensorMAIN PCB CN60 and CN90 connectorsR228 resistor (IC01 MICOM #12)

How to Fix

  1. 1

    Check CN60 and CN90 connector insertion

  2. 2

    Measure voltage between CN60 pin 5 (W/BLU) and CN90 pin 8

  3. 3

    Measure resistance between same pins

  4. 4

    Compare to temperature table DATA1

  5. 5

    Verify actual ambient temperature

Need more help with your Samsung RF28T5021B1?