Error Code COMPRESSOR_ERROR
Compressor not starting or running properly due to electrical or mechanical failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Compressor Not Running
What This Means
5-minute startup delay after power ON (normal for protection); Compressor locked or mechanical jam; Bad connector contact at CN102; Inverter circuit failure (IGBT or control circuit); Wiring disconnection from MAIN PCB; DC 15V or AC 115V supply failure; Overload protection activation
What actually causes this:
The compressor motor cannot start due to power supply failure, electrical disconnection, or internal mechanical failure
First Thing to Check
Wait at least 10 minutes after power off; check power plug; verify AC power at outlet
Parts Involved
How to Fix
- 1
Wait 10 minutes minimum after power OFF before restarting (7-minute minimum protects compressor)
- 2
In forced operation mode, verify compressor activation
- 3
Check DC 15V at ZD501
- 4
Verify AC 115V at CN81
- 5
Check compressor connector CN102 insertion
- 6
Verify DC 5V at C1009
- 7
Check F-Sensor reading and forced operation signal
Other Error Codes for RF28T5021SR
Refrigerator compartment temperature sensor is disconnected or dead
Internal humidity sensor has failed or is disconnected
Defrost sensor on freezer evaporator is failed or disconnected
Freezer fan motor is not running or not sending feedback
Supply voltage to compressor is too high
Freezer temperature sensor is failing or disconnected
Ice maker temperature sensor in freezer is failed or unplugged
External room temperature sensor is failed or disconnected